Hot

Male Connector SAE/MS Straight Thread

Truelok
Ordering Number
T
Tube O.D.
SAE
Thread Size
ACDE
Minimum
Opening
Fx
Hex Flat
G
Hex
Flat
HP
inchinchinchinchinchinchinchinchinchinch
MCST-125-312-SE1/85/16-2410180.50 0.600.097/167/160.920.30
MCST-250-7/16-20-SE1/47/16-201.340.600.700.199/16 9/161.050.36
MCST-250-9/16-181/49/16-181.400.600.700.1911/16 9/161.110.39
MCST-250-3/4-16-SE1/43/4-161.480.600.700.197/89/161.190.44
MCST-250-7/8-14-SE1/47/8-141.600.600.700.1919/161.310.50
MCST-375-7/16-20-SE3/87/16-201.400.660.760.205/811/161.110.36
MCST-375-9/16-18-SE3/89/16-181.460.660.760.2811/1611/161.170.39
MCST-375-3/4-16-SE3/83/4-161.540.660.760.287/811/161.250.44
MCST-375-7/8-14-SE3/87/8-141.660.660.760.28111/161.370.50
MCST-500-9/16-18-SE1/29/16-181.540.900.860.2813/16 7/81.140.39
MCST-500-3/4-16-SE1/23/4-161.650.900.860.417/8 7/81.250.44
MCST-500-7/8-14-SE 1/27/8-141.770.900.860.411 7/81.370.50
MCST-500-17/16-12-SE1/211/16-121.930.900.860.4111/147/81.530.59

Description

Material:
Truelok® standard Compression Tube Fittings Male Adapter are manufactured by using SS316 Bar Stock in accodance with ASTM A-479 and SS316 Forging in accordance with ASTM A-182. Fittings in other materials are available at customer’s request.

Operating Temperature:
Truelok® Compression Tube Fittings Male Adapter provide safe and reliable performance from cyrogenic temperature to high temperature upto 380 °C.

Working Pressure:

The maximum working pressure of standard Compression Tube Fittings Male Adapter, when used in conjunction with annealed SS316 seamless tubing per ASTM A-213 or equivalent, is shown below:

PSIG(Pound Square Per Inch)

Tube O.D.
(inches)
Wall Thickness of Tube (inches)
0.0100.0120.0140.0160.0200.0280.0350.0490.0650.0830.0950.109
Working Pressure, psig
1/16560068008100940012100
1/8850010900
1/4400051007500 10200
3/8330048006500
1/22600370051006700
3/424003300420049005800
12400310036004200

Reviews